You're in Electrical Supplies
Need a Personal Shopper?
Subscribe to
Bizrate emails for the hottest
deals & products,
PLUS a chance to
WIN $25
sign me up!
New winners chosen weekly.
No purchase necessary.
Best Seller | DAYTON 103857.00 Capacitor-Start/Run General Purpose Motor, 1/3 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 1/3 HP, Nameplate RPM 1,140, No. of Speeds 1, Voltage 115/208-230V AC, Full Load Amps 3.4/1.8-1.7 A, 56 Frame, Hz 60 Hz, Motor Service Factor 1.35, Max. Ambient Temp. 104 Degrees F,... ... more | go to store |
DAYTON 6XJ36 Capacitor-Start/Run General Purpose Motor, 1, 1/3 HP, 208-230V AC General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 1, 1/3 HP, Nameplate RPM 1,725/1,140, No. of Speeds 2, Voltage 208-230V AC, Full Load Amps 5.2-5.0/3.5 A, 56 Frame, Hz 60 Hz, Motor Service Factor 1.15, Max. Ambient Temp. 104... ... more | go to store |
DAYTON 6XJ34 Capacitor-Start/Run General Purpose Motor, 1, 1/3 HP, 115V AC General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 1, 1/3 HP, Nameplate RPM 1,725/1,140, No. of Speeds 2, Voltage 115V AC, Full Load Amps 10.1/7.1 A, 56 Frame, Hz 60 Hz, Motor Service Factor 1.15, Max. Ambient Temp. 104 Degrees F,... ... more | go to store |
DAYTON 103814.00 Capacitor-Start/Run General Purpose Motor, 1/2 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 1/2 HP, Nameplate RPM 3,450, No. of Speeds 1, Voltage 115/208-230V AC, Full Load Amps 4.4/2.4-2.2 A, 48 Frame, Hz 60 Hz, Motor Service Factor 1.25, Max. Ambient Temp. 104 Degrees F,... ... more | go to store |
DAYTON 119191.00 Capacitor-Start/Run General Purpose Motor, 1/2 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 1/2 HP, Nameplate RPM 1,140, No. of Speeds 1, Voltage 115/208-230V AC, Full Load Amps 5.6/3.0-2.8 A, 56 Frame, Hz 60 Hz, Motor Service Factor 1.25, Max. Ambient Temp. 104 Degrees F,... ... more | go to store |
DAYTON 103805.00 Capacitor-Start/Run General Purpose Motor, 1/2 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 1/2 HP, Nameplate RPM 3,450, No. of Speeds 1, Voltage 115/208-230V AC, Full Load Amps 4.4/2.4-2.2 A, 48 Frame, Hz 60 Hz, Motor Service Factor 1.25, Max. Ambient Temp. 104 Degrees F,... ... more | go to store |
DAYTON 119170.00 Capacitor-Start/Run General Purpose Motor, 1 1/2 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 1 1/2 HP, Nameplate RPM 1,725, No. of Speeds 1, Voltage 115/208-230V AC, Full Load Amps 12.6/6.9-6.3 A, 56H Frame, Hz 60 Hz, Motor Service Factor 1.15, Max. Ambient Temp. 104... ... more | go to store |
DAYTON 103815.00 Capacitor-Start/Run General Purpose Motor, 1/4 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 1/4 HP, Nameplate RPM 1,725, No. of Speeds 1, Voltage 115/208-230V AC, Full Load Amps 2.4/1.2-1.2 A, 48 Frame, Hz 60 Hz, Motor Service Factor 1.35, Max. Ambient Temp. 104 Degrees F,... ... more | go to store |
DAYTON 119157.00 Capacitor-Start/Run General Purpose Motor, 3/4 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 3/4 HP, Nameplate RPM 1,725, No. of Speeds 1, Voltage 115/208-230V AC, Full Load Amps 6.6/3.5-3.3 A, 56 Frame, Hz 60 Hz, Motor Service Factor 1.25, Max. Ambient Temp. 104 Degrees F,... ... more | go to store |
DAYTON 103840.00 Capacitor-Start/Run General Purpose Motor, 3/4 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 3/4 HP, Nameplate RPM 3,450, No. of Speeds 1, Voltage 115/208-230V AC, Full Load Amps 7.2/4.0-3.6 A, 56 Frame, Hz 60 Hz, Motor Service Factor 1.25, Max. Ambient Temp. 104 Degrees F,... ... more | go to store |
DAYTON 103808.00 Capacitor-Start/Run General Purpose Motor, 1/2 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 1/2 HP, Nameplate RPM 1,725, No. of Speeds 1, Voltage 115/208-230V AC, Full Load Amps 4.6/2.4-2.3 A, 48 Frame, Hz 60 Hz, Motor Service Factor 1.25, Max. Ambient Temp. 104 Degrees F,... ... more | go to store |
DAYTON 119172.00 Capacitor-Start/Run General Purpose Motor, 1 1/2 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 1 1/2 HP, Nameplate RPM 1,725, No. of Speeds 1, Voltage 115/208-230V AC, Full Load Amps 12.6/6.9-6.3 A, 56HZ Frame, Hz 60 Hz, Motor Service Factor 1.15, Max. Ambient Temp. 104... ... more | go to store |
DAYTON 119192.00 Capacitor-Start/Run General Purpose Motor, 3/4 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 3/4 HP, Nameplate RPM 1,140, No. of Speeds 1, Voltage 115/208-230V AC, Full Load Amps 6.7/3.7-3.35 A, 56H Frame, Hz 60 Hz, Motor Service Factor 1.15, Max. Ambient Temp. 104 Degrees... ... more | go to store |
DAYTON 103876.00 Capacitor-Start/Run General Purpose Motor, 1/2 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 1/2 HP, Nameplate RPM 1,725, No. of Speeds 1, Voltage 115/208-230V AC, Full Load Amps 4.6/2.4-2.3 A, 56C Frame, Hz 60 Hz, Motor Service Factor 1.25, Max. Ambient Temp. 104 Degrees... ... more | go to store |
MARATHON MOTORS 145TBFR5303 Capacitor-Start/Run General Purpose Motor, 2 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 2 HP, Nameplate RPM 3,510, No. of Speeds 1, Voltage 115/208-230V AC, Full Load Amps 18.0/10.0-9.0 A, 145T Frame, Usable @ 208V Yes, Usable @ 200V No, Hz 60 Hz, Motor Service Factor... ... more | go to store |
MARATHON MOTORS 056B34F5327 Capacitor-Start/Run General Purpose Motor, 2 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 2 HP, Nameplate RPM 3,450, No. of Speeds 1, Voltage 115/208-230V AC, Full Load Amps 16.6/9.4-8.3 A, 56HC Frame, Usable @ 208V Yes, Usable @ 200V No, Hz 60 Hz, Motor Service Factor... ... more | go to store |
MARATHON MOTORS 056B34D11016 Capacitor-Start/Run General Purpose Motor, 3/4 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 3/4 HP, Nameplate RPM 3,450, No. of Speeds 1, Voltage 115/230V AC, Full Load Amps 7.2/3.6 A, 56C Frame, Usable @ 208V No, Usable @ 200V No, Hz 60 Hz, Motor Service Factor 1.25, Max.... ... more | go to store |
MARATHON MOTORS 145TBFR5334 Capacitor-Start/Run General Purpose Motor, 2 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 2 HP, Nameplate RPM 1,740, No. of Speeds 1, Voltage 115/230V AC, Full Load Amps 18.8/9.4 A, 145T Frame, Usable @ 208V No, Usable @ 200V No, Hz 60 Hz, Motor Service Factor 1.15, Max.... ... more | go to store |
MARATHON MOTORS 056B17D11030 Capacitor-Start/Run General Purpose Motor, 1/2 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 1/2 HP, Nameplate RPM 1,725, No. of Speeds 1, Voltage 115/230V AC, Full Load Amps 4.6/2.3 A, 56 Frame, Usable @ 208V No, Usable @ 200V No, Hz 60 Hz, Motor Service Factor 1.25, Max.... ... more | go to store |
MARATHON MOTORS 056B17D11029 Capacitor-Start/Run General Purpose Motor, 1/2 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 1/2 HP, Nameplate RPM 1,725, No. of Speeds 1, Voltage 120/240V AC, Full Load Amps 5.2-4.4/2.6-2.2 A, 56C Frame, Usable @ 208V No, Usable @ 200V No, Hz 60/50 Hz, Motor Service Factor... ... more | go to store |
DAYTON 103875.00 Capacitor-Start/Run General Purpose Motor, 1/2 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 1/2 HP, Nameplate RPM 1,725, No. of Speeds 1, Voltage 115/208-230V AC, Full Load Amps 4.6/2.4-2.3 A, 56 Frame, Hz 60 Hz, Motor Service Factor 1.25, Max. Ambient Temp. 104 Degrees F,... ... more | go to store |
MARATHON MOTORS 5KCR49UN0107 Capacitor-Start/Run General Purpose Motor, 1 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 1 HP, Nameplate RPM 1,725, No. of Speeds 1, Voltage 115/230V AC, Full Load Amps 11.8-11.4/5.9-5.7 A, 56C Frame, Usable @ 208V Yes, Usable @ 200V Yes, Hz 60 Hz, Motor Service Factor... ... more | go to store |
MARATHON MOTORS 5KCR49UN0106X Capacitor-Start/Run General Purpose Motor, 1 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 1 HP, Nameplate RPM 1,725, No. of Speeds 1, Voltage 115/230V AC, Full Load Amps 11.8-11.4/5.9-5.7 A, 56C Frame, Usable @ 208V Yes, Usable @ 200V Yes, Hz 60 Hz, Motor Service Factor... ... more | go to store |
MARATHON MOTORS 056B34D11018 Capacitor-Start/Run General Purpose Motor, 1/3 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 1/3 HP, Nameplate RPM 3,450, No. of Speeds 1, Voltage 115/230V AC, Full Load Amps 3.0/1.5 A, 56C Frame, Usable @ 208V No, Usable @ 200V No, Hz 60 Hz, Motor Service Factor 1.35, Max.... ... more | go to store |
MARATHON MOTORS 056B17D11014 Capacitor-Start/Run General Purpose Motor, 1/3 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 1/3 HP, Nameplate RPM 1,725, No. of Speeds 1, Voltage 115/230V AC, Full Load Amps 3.8/1.9 A, 56C Frame, Usable @ 208V No, Usable @ 200V No, Hz 60 Hz, Motor Service Factor 1.35, Max.... ... more | go to store |
MARATHON MOTORS 5KC36LN1X Capacitor-Start General Purpose Motor, 1/3 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start, 1/3 HP, Nameplate RPM 1,725, No. of Speeds 1, Voltage 115/208-230V AC, Full Load Amps 6.0/3.2-3.0 A, 56 Frame, Usable @ 208V Yes, Usable @ 200V No, Hz 60 Hz, Motor Service Factor 1.35,... ... more | go to store |
MARATHON MOTORS 5KC36LN26 Capacitor-Start General Purpose Motor, 1/3 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start, 1/3 HP, Nameplate RPM 1,725, No. of Speeds 1, Voltage 115/208-230V AC, Full Load Amps 6.0/3.2-3.0 A, 48 Frame, Usable @ 208V Yes, Usable @ 200V No, Hz 60 Hz, Motor Service Factor 1.35,... ... more | go to store |
MARATHON MOTORS 048C17D2028 Capacitor-Start General Purpose Motor, 1/3 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start, 1/3 HP, Nameplate RPM 1,725, No. of Speeds 1, Voltage 115/230V AC, Full Load Amps 7.0/3.5 A, 48 Frame, Usable @ 208V No, Usable @ 200V No, Hz 60 Hz, Motor Service Factor 1, Max. Ambient... ... more | go to store |
MARATHON MOTORS 048C17D2029 Capacitor-Start General Purpose Motor, 1/3 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start, 1/3 HP, Nameplate RPM 1,725, No. of Speeds 1, Voltage 115/230V AC, Full Load Amps 7.0/3.5 A, 48 Frame, Usable @ 208V No, Usable @ 200V No, Hz 60 Hz, Motor Service Factor 1, Max. Ambient... ... more | go to store |
MARATHON MOTORS 056C11F5303 Capacitor-Start General Purpose Motor, 1/3 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start, 1/3 HP, Nameplate RPM 1,140, No. of Speeds 1, Voltage 115/208-230V AC, Full Load Amps 7.8/3.6-3.9 A, 56C Frame, Usable @ 208V Yes, Usable @ 200V No, Hz 60 Hz, Motor Service Factor 1.15,... ... more | go to store |
MARATHON MOTORS 048C17D2023 Capacitor-Start General Purpose Motor, 1/3 HP, General Purpose Motor, Single Phase, Motor Design Capacitor-Start, 1/3 HP, Nameplate RPM 1,725, No. of Speeds 1, Voltage 115/230V AC, Full Load Amps 7.0/3.5 A, 48 Frame, Usable @ 208V No, Usable @ 200V No, Hz 60 Hz, Motor Service Factor 1, Max. Ambient... ... more | go to store |
DAYTON 30PT50 Capacitor-Start/Run General Purpose Motor, 1/4 HP, 115/230V AC General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 1/4 HP, Nameplate RPM 1,140, No. of Speeds 1, Voltage 115/230V AC, Full Load Amps 3.7/1.9 A, 56 Frame, Hz 60 Hz, Motor Service Factor 1.35, Max. Ambient Temp. 104 Degrees F, Motor... ... more | go to store |
DAYTON 5UKG3 Capacitor-Start/Run General Purpose Motor, 2 HP, 115/208-230V AC General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 2 HP, Nameplate RPM 3,450, No. of Speeds 1, Voltage 115/208-230V AC, Full Load Amps 19.5/10.8-9.7 A, 56H Frame, Hz 60 Hz, Motor Service Factor 1.15, Max. Ambient Temp. 104 Degrees... ... more | go to store |
DAYTON 5K677 Capacitor-Start/Run General Purpose Motor, 7 1/2 HP, 230V AC General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 7 1/2 HP, Nameplate RPM 1,740, No. of Speeds 1, Voltage 230V AC, Full Load Amps 35.5 A, 215T Frame, Hz 60 Hz, Motor Service Factor 1.15, Max. Ambient Temp. 104 Degrees F, Motor... ... more | go to store |
DAYTON 6K562BG Capacitor-Start/Run General Purpose Motor, 1 HP, 115/208-230V AC General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 1 HP, Nameplate RPM 1,725, No. of Speeds 1, Voltage 115/208-230V AC, Full Load Amps 9.9/5.2-5.0 A, 56H Frame, Hz 60 Hz, Motor Service Factor 1.15, Max. Ambient Temp. 104 Degrees F,... ... more | go to store |
DAYTON 3K300 Capacitor-Start/Run General Purpose Motor, 1 1/2 HP, 115/208-230V General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 1 1/2 HP, Nameplate RPM 3,450, No. of Speeds 1, Voltage 115/208-230V AC, Full Load Amps 14.6/8.1-7.4 A, 143T Frame, Hz 60 Hz, Motor Service Factor 1, Max. Ambient Temp. 104 Degrees... ... more | go to store |
DAYTON 5K967 Capacitor-Start/Run General Purpose Motor, 3 HP, 115/230V AC General Purpose Motor, Single Phase, Motor Design Capacitor-Start/Run, 3 HP, Nameplate RPM 1,740, No. of Speeds 1, Voltage 115/230V AC, Full Load Amps 30.0/15.0 A, 184T Frame, Hz 60 Hz, Motor Service Factor 1, Max. Ambient Temp. 104 Degrees F, Motor... ... more | go to store |
Ads related to DAYTON 103813.00 Capacitor-Start/Run General Purpose Motor, 1/3 HP,